Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Oncol ; 13: 1200270, 2023.
Article in English | MEDLINE | ID: mdl-37588094

ABSTRACT

Prostate cancer patients undergoing external beam radiation therapy (EBRT) benefit from a full bladder to decrease bowel and bladder toxicity. Ultrasound may offer a proxy metric for evaluation, sparing CBCT dosing. Patients were prospectively enrolled pre-simulation from January 2017 to February 2018. Bladder volume was evaluated prior to RT using US daily and CBCT for three daily treatments and then weekly unless otherwise indicated. 29 patients completed median 40 days of RT, resulting in 478 CBCT and 1,099 US bladder volumes. 21 patients were treated to intact glands and 8 to the post-prostatectomy bed. Median patient age was 70 years. Bladder volume on CBCT and US positively correlated (r = 0.85), with average bladder volume for all patients of 162 mL versus 149 mL, respectively. Bladder volume during treatment was consistently lower than the volume at CT simulation (153 mL vs 194 mL, p<0.01) and progressively declined during treatment. Patients older than 70 years presented with lower average bladder volumes than those < 70 years (122 mL vs 208 mL, respectively, p<0.01). Patients with the highest agreement between CBCT and US (<10% variability) had higher average bladder volumes (192 mL vs 120 mL, p=0.01). US was found to be an accurate measure of bladder volume and may be used to monitor daily bladder volumes in patients being treated with radiation for prostate cancer.

2.
J Neurooncol ; 148(2): 273-279, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32474748

ABSTRACT

PURPOSE: To investigate the frequency, magnitude and possible causes of frame-shifts that may occur between treatment planning and treatment delivery when performing Gamma Knife radiosurgery with rigid frame-based immobilization. METHODS: Differences between computed tomography (CT) framed fiducial stereotactic coordinate reference and cone beam computed tomography stereotactic coordinates after image registration were recorded for 49 frame-based GK radiosurgery cases performed using the Gamma Knife Icon. Parameters recorded include rotational shifts, translational shifts, and the GK-computed Maximum Shot Displacement (MSD) between the two stereotactic coordinate spaces. Other patient-specific parameters were collected and linear regression analysis was performed to evaluate predictors of increased displacement. RESULTS: The median values of rotational shifts were: pitch 0.14°, yaw 0.17°, and roll 0.13°. The median absolute values of translational shifts were: left-right 0.39 mm, anteroposterior 0.14 mm, and superior-inferior 0. 22 mm. The median value of MSD was 0.71 mm. Twelve cases (24.5%) had a MSD of greater than 1.0 mm. Male gender was associated with increased MSD (p = 0.013) and translational shifts (root-mean-squared value, p = 0.017). Cases with large differences between right and left sided pin lengths were also associated with increased MSD (p = 0.011). CONCLUSIONS: The use of CBCT image guidance in frame-based GK radiosurgery allows unintended frame shifts to be identified and corrected. A significant fraction (24.5%) of patients had large enough shifts to result in a MSD of greater than 1.0 mm. Male gender and eccentrically placed frames were associated with increased MSD, and particular care should be taken in these cases.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Cone-Beam Computed Tomography/methods , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Artifacts , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...